Hydrogen gas generator

Sort By:  
Purity 99.99999%
Purity 99.9999%
Hydrogen and air generator
Hydrogen and air generator
Purity 99.99999%
Purity 99.9999%
Flow rate: 100 to 250 ml/min, Purity 99.9996%
Flow rate: 100 to 1000 ml/min, Purity 99.99999%
Flow rate: 100 to 600 ml/min, Purity 99.9999%
e-Gas 19" RACK-NM (EL70087)

The e-Gas 19" Rack Plus series hydrogen generators use the latest proton exchange membrane (PEM) technology to produce high purity hydrogen. The exclusive “No Maintenance” gas column cold regeneration system eliminates all the down time for maintenance that is typical of other systems on the market, assuring the best hydrogen purity at all times.

The e-Gas 19” Rack Plus series generators are ideal for:
• Flame ionization detector (FID)
• Carrier gas for GC and GC-MS (NM version)
• Fast GC (NM version)
• Collisions on ICP-MS
• Small fuel-cell cylinder refills

NM PLUS SERIES FEATURES:
• Flow rate from 100 to 1000 ml/min (NM), to 600 ml/min (PG)
• Purity 99.99996%(NM), Purity 99.9996%(PG)
• Pressure up to 11 bar (160 psig)
• No maintenance
• Unique patented automatic dryer system
• Unique 100% titanium electrolytic cell
• 2 year standard warranty

NM PLUS SERIES BENEFITS

CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium. Run time savings of 25% to 35% without a decline in resolution.

IMPROVED SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

LONGER ANALYTICAL COLUMN LIFE
The use of hydrogen as a carrier gas allows lower temperature elution, thus extending the life of the chromatograph column.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.

Specifications
e-Gas 19" RACK-NM Plus series

Models(H2)

e-Gas RACK NM 100

e-Gas RACK NM 160

e-Gas RACK NM 250

e-Gas RACK NM 300

e-Gas RACK NM 500

e-Gas RACK NM 600

e-Gas RACK NM 1000

Flow rate (ml/min)

100

160

250

300

500

600

1000

Purity

99.99999%

Display

LCD touch screen interface or push bottoms

Membrane

Polymer Electrolyte Membrane(PEM)

Dryer

Exclusive cold dual dynamic regeneration system

Outlet Pressure

Adjustable by electronic controller up to 11 bar (160 psig)

Water quality

Deionized or demineralized (<2μs)

Dimensions(mm)

19" standard RACK

Connection

Software upgrade by standard USB

Certifications

CE, CSA, FCC

 

Purity 99.99999%
e-Gas 19" RACK-PG (EL70088)

The e-Gas 19" Rack series hydrogen generators use the latest proton exchange membrane (PEM) technology to produce high purity hydrogen. The exclusive “No Maintenance” gas column cold regeneration system eliminates all the down time for maintenance that is typical of other systems on the market, assuring the best hydrogen purity at all times.

The e-Gas 19” Rack series generators are ideal for:
• Flame ionization detector (FID)
• Carrier gas for GC and GC-MS (NM version)
• Fast GC (NM version)
• Collisions on ICP-MS
• Small fuel-cell cylinder refills

PG SERIES FEATURES:
• Flow rate from 100 to 1000 ml/min (NM), to 600 ml/min (PG)
• Purity 99.99996%(NM), Purity 99.9996%(PG)
• Pressure up to 11 bar (160 psig)
• No maintenance
• Unique patented automatic dryer system
• Unique 100% titanium electrolytic cell
• 2 year standard warranty

PG SERIES BENEFITS

CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium. Run time savings of 25% to 35% without a decline in resolution.

IMPROVED SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

LONGER ANALYTICAL COLUMN LIFE
The use of hydrogen as a carrier gas allows lower temperature elution, thus extending the life of the chromatograph column.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.

Specifications
e-Gas 19" RACK-PG series

Models(H2)

e-Gas RACK PG 100

e-Gas RACK PG 160

e-Gas RACK PG 250

e-Gas RACK PG 300

e-Gas RACK PG 500

e-Gas RACK PG 600

Flow rate (ml/min)

100

160

250

300

500

600

Purity

99.9999%

Display

LCD touch screen interface or push bottoms

Membrane

Polymer Electrolyte Membrane(PEM)

Outlet Pressure

Adjustable by electronic controller up to 11 bar (160 psig)

Water quality

Deionized or demineralized (<2μs)

Dimensions(mm)

19" standard RACK

Connection

Software upgrade by standard USB

Certi_cations

CE, CSA, FCC


Purity 99.9999%
e-Gas FID FLAT-NM (EL70086)

The e-Gas FID STATION hydrogen and air generator uses the latest proton exchange membrane (PEM) technology to produce pure hydrogen. The hydrogen is ideal for use in gas chromatographic detectors such as FID, NPD, and TCD, and as a reagent gas for ELCD and HALL.

The horizontal format is designed to sit under and support the weight of your GC, optimizing bench space.  At only 17 cm high, the generator will still allow easy access to the injectors of any GC on the market. De-ionized water is automatically loaded from smart internal system tanks with a 3 litre capacity, providing up to 3000 litres of H2 before a refill is required.  The only recommended maintenance is replacement of the internal deionizing cartridge, which has been greatly simplified.

FID Station PLUS models produce an H2 flow of up to  600cc/min with a purity of 6.0, or up to 1000cc/min with a purity of 7.0. The optional zero air generator provides 1.8 l/min or 5 l/min of zero air with HC content around 0.5ppm.

FID Station Plus FEATURES

USER-FRIENDLY CONTROLS
Full microprocessor control
LCD touch screen interface or push buttons: real time outlet pressure, water quality, auto diagnostics, leak detectors, water level, and quality sensors

POWERFUL WATER PUMP
Optimized powerful water pump for PEM cell

CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

FID Station Plus BENEFITS

SAVINGS
Hydrogen gas generators eliminate the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles. The dual configuration H2 or H2 + Air, available in a single instrument, saves space and money.

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium, providing run time savings of 25% to 35% without a decline in resolution.

EASY USE AND MAINTAINENCE
The unit features remote software control via RS232, USB, or intranet. With automatic cold dryer regeneration, there are no caustic solutions used. Maintenance is simplified by our deionizer bag access system, which allows changing out the deionizer bag without tools, without even turning off the instrument.

IMPROVED SAFETY
The very small internal volume (less than 50 ml) allows safe use of gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunction. An optional hydrogen sensor is available for monitoring the oven-LEL of the GC. The VICI DBS Plus series also includes additional security features like a shock sensor to prompt shutdown in the event of an earthquake.

INCREASED PRODUCTIVITY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and maintenance of the drying system.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.  

Specifications
e-Gas FID FLAT-PG Plus series for all GC Detectors Applications

Models(H2)

e-Gas FID FLAT NM 100

e-Gas FID FLAT NM 300

e-Gas FID FLAT NM 600

e-Gas FID FLAT NM 1000

Flow rate (ml/min)

100

300

600

1000

Weight (kg)

approximated 35

Purity

99.99999%

Display

Operating parameters, system status, alarms and touch screen

LED Indicators

Power on/off, system ready, errors

Membrane

Polymer Electrolyte Membrane(PEM)

Dryer

Exclusive cold dual dynamic regeneration system

Max Outlet Pressure

11 bar (160 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<2μs)

Internal water tank system

7L autore_ll included

Cascading

The exclusive cascading option allows up to 32 units to be connected in series

Connections

1/8 swagelock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

690W x 150H x 680D

Tested weight support (kg)

80

Connection

USB mod A

Certifications

CE, CSA, FCC

Options

RS232/RS485 and USB, external contacts, PC software, Manage & Control, Intranet

Hydrogen and air generator
e-Gas FID FLAT-PG (EL70085)

The e-Gas FID STATION hydrogen and air generator uses the latest proton exchange membrane (PEM) technology to produce pure hydrogen. The hydrogen is ideal for use in gas chromatographic detectors such as FID, NPD, and TCD, and as a reagent gas for ELCD and HALL.

The horizontal format is designed to sit under and support the weight of your GC, optimizing bench space.  At only 17 cm high, the generator will still allow easy access to the injectors of any GC on the market. De-ionized water is automatically loaded from smart internal system tanks with a 3 litre capacity, providing up to 3000 litres of H2 before a refill is required.  The only recommended maintenance is replacement of the internal deionizing cartridge, which has been greatly simplified.

FID Station PLUS models produce an H2 flow of up to  600cc/min with a purity of 6.0, or up to 1000cc/min with a purity of 7.0. The optional zero air generator provides 1.8 l/min or 5 l/min of zero air with HC content around 0.5ppm.

FID Station Plus FEATURES

USER-FRIENDLY CONTROLS
Full microprocessor control
LCD touch screen interface or push buttons: real time outlet pressure, water quality, auto diagnostics, leak detectors, water level, and quality sensors

POWERFUL WATER PUMP
Optimized powerful water pump for PEM cell

CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

FID Station Plus BENEFITS

SAVINGS
Hydrogen gas generators eliminate the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles. The dual configuration H2 or H2 + Air, available in a single instrument, saves space and money.

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium, providing run time savings of 25% to 35% without a decline in resolution.

EASY USE AND MAINTAINENCE
The unit features remote software control via RS232, USB, or intranet. With automatic cold dryer regeneration, there are no caustic solutions used. Maintenance is simplified by our deionizer bag access system, which allows changing out the deionizer bag without tools, without even turning off the instrument.

IMPROVED SAFETY
The very small internal volume (less than 50 ml) allows safe use of gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunction. An optional hydrogen sensor is available for monitoring the oven-LEL of the GC. The VICI DBS Plus series also includes additional security features like a shock sensor to prompt shutdown in the event of an earthquake.

INCREASED PRODUCTIVITY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and maintenance of the drying system.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.  

Specifications
e-Gas FID FLAT-PG Plus series for all GC Detectors Applications

Models (H2)

e-Gas FID FLAT PG 100

e-Gas FID FLAT PG 250

Flow rate (ml/min)

100

250

Weight (kg)

approximated 40

Purity

99.9999%

Display

Operating parameters, system status, alarms and touch screen

LED Indicators

Power on/off, system ready, errors

Membrane

Polymer Electrolyte Membrane(PEM)

Max Outlet Pressure

11 bar (160 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<2μs)

Internal water tank system

7L autore_ll included

Cascading

The exclusive cascading option allows up to 32 units to be connected in series

Connections

1/8 swage lock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

690W x 150H x 680D

Tested weight support (kg)

80

Connection

USB mod A

Certifications

CE, CSA, FCC

Options

RS232/RS485 and USB, autore_ll, external contacts, PC control, Intranet

Hydrogen and air generator
e-Gas FID TOWER-NM (EL70083)

The space-saving FID Tower PLUS hydrogen and air generator uses the latest proton exchange membrane (PEM) technology to produce pure hydrogen.  Two configurations are offered --  the high purity PG Plus and the ultra-high purity NM plus -- with flow ranges up to 1 l/min for H2 and 5 l/min for zero air.  The optional Zero Air generator provides zero air with HC content around 0.5ppm. (Oil-free compressor not included.) 

De-ionized water is automatically loaded from smart internal system tanks with a 3 litre capacity, providing up to 3000 litres of H2 before a refill is required.  The only recommended maintenance is replacement of the internal deionizing cartridge, which has been greatly simplified.

FID Tower Plus FEATURES

USER-FRIENDLY CONTROLS
Full microprocessor control
LCD touch screen interface or push buttons: real time outlet pressure, water quality, auto diagnostics, leak detectors, water level, and quality sensors

POWERFUL WATER PUMP
Optimized powerful water pump for PEM cell

CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

FID Tower Plus BENEFITS

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles. The dual configuration H2 or H2 + Air, available in a single instrument, saves space and money.

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium, providing run time savings of 25% to 35% without a decline in resolution.

EASY TO USE AND MAINTAIN
The unit features remote software control via RS232, USB, or intranet. With automatic cold dryer regeneration, there are no caustic solutions used. Maintenance is simplified by our deionizer bag access system, which allows changing out the deionizer bag without tools, without even turning off the instrument.

IMPROVED SAFETY
The very small internal volume (less than 50 ml) allows safe use of gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunction. An optional hydrogen sensor is available for monitoring the oven-LEL of the GC. The VICI DBS Plus series also includes additional security features like a shock sensor to prompt shutdown in the event of an earthquake.

INCREASED PRODUCTIVITY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and maintenance of the drying system.

Specifications
FID TOWER-NM Plus series
for all GC Detectors and Carrier Gas Applications

Models(H2)

e-Gas FID TOWER NM 100

e-Gas FID TOWER NM 160

e-Gas FID TOWER NM 250

e-Gas FID TOWER NM 300

e-Gas FID TOWER NM 500

e-Gas FID TOWER NM 600

e-Gas FID TOWER NM 1000

Flow rate (ml/min)

100

160

250

300

500

600

1000

Weight (kg)

approximated 35

Purity

99.99999%

Display

Operating parameters, system status, alarms and touch screen

LED Indicators

Power on/off, system ready, errors

Membrane

Polymer Electrolyte Membrane(PEM)

Dryer

Exclusive cold dual dynamic regeneration system

Max Outlet Pressure

11 bar (160 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<2μs)

Internal water tank system

7L autore_ll included

Cascading

The exclusive cascading option allows up to 32 units to be connected in series

Connections

1/8 swage lock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

140W×490H×580D

Connection

USB mod A

Certifications

CE, CSA, FCC

Options

RS232/RS485 and USB, external contacts, PC software,Manage & Control, Intranet

Purity 99.99999%
e-Gas FID TOWER-PG (EL70084)

The space-saving FID Tower PLUS hydrogen and air generator uses the latest proton exchange membrane (PEM) technology to produce pure hydrogen.  Two configurations are offered --  the high purity PG Plus and the ultra-high purity NM plus -- with flow ranges up to 1 l/min for H2 and 5 l/min for zero air.  The optional Zero Air generator provides zero air with HC content around 0.5ppm. (Oil-free compressor not included.) 

De-ionized water is automatically loaded from smart internal system tanks with a 3 litre capacity, providing up to 3000 litres of H2 before a refill is required.  The only recommended maintenance is replacement of the internal deionizing cartridge, which has been greatly simplified.

FID Tower Plus FEATURES

USER-FRIENDLY CONTROLS
Full microprocessor control
LCD touch screen interface or push buttons: real time outlet pressure, water quality, auto diagnostics, leak detectors, water level, and quality sensors

POWERFUL WATER PUMP
Optimized powerful water pump for PEM cell

CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

FID Tower Plus BENEFITS

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles. The dual configuration H2 or H2 + Air, available in a single instrument, saves space and money.

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium, providing run time savings of 25% to 35% without a decline in resolution.

EASY TO USE AND MAINTAIN
The unit features remote software control via RS232, USB, or intranet. With automatic cold dryer regeneration, there are no caustic solutions used. Maintenance is simplified by our deionizer bag access system, which allows changing out the deionizer bag without tools, without even turning off the instrument.

IMPROVED SAFETY
The very small internal volume (less than 50 ml) allows safe use of gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunction. An optional hydrogen sensor is available for monitoring the oven-LEL of the GC. The VICI DBS Plus series also includes additional security features like a shock sensor to prompt shutdown in the event of an earthquake.

INCREASED PRODUCTIVITY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and maintenance of the drying system.

Specifications
FID TOWER-NM Plus series
for all GC Detectors and Carrier Gas Applications

Models (H2)

e-Gas FID TOWER PG 100

e-Gas FID TOWER PG 160

e-Gas FID TOWER PG 250

e-Gas FID TOWER PG 300

e-Gas FID TOWER PG 500

e-Gas FID TOWER PG 600

Flow rate (ml/min)

100

160

250

300

500

600

Weight (kg)

approximated 35

Purity

99.9999%

Display

Operating parameters, system status, alarms and touch screen

LED Indicators

Power on/off, system ready, errors

Membrane

Polymer Electrolyte Membrane(PEM)

Max Outlet Pressure

11 bar (160 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<2μs)

Internal water tank system

7L autore_ll included

Cascading

The exclusive cascading option allows up to 32 units to be connected in series

Connections

1/8 swage lock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

140W×490H×580D

Connection

USB mod A

Certifications

CE, CSA, FCC

Options

RS232/RS485 and USB, autore_ll, external contacts, PC control, Intranet

Purity 99.9999%
e-Gas KH Plus (EL70080)
EZZILAB Hydrogen Generators offer a safe, economical, and convenient alternative to gas cylinders. The HK Plus Series provides superior performance with proprietary electrolytic cell technology combined with high quality components and a unique hydrogen drying solution. Ideal for use with gas chromatography detectors such as FID, NPD, and TCD.

e-Gas HK PLUS SERIES FEATURES:
• Flow rate from 100 to 250 ml/min
• Purity 99.9996%
• Pressure up to 7 bar (100 psig)
• Minimal maintenance
• Unique drying membrane - no desiccant cartridges required
• Unique 100% titanium electrolytic cell
• 2 year standard warranty

Benefits

IMPROVED SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.

Specifications

Modes

E-Gas HKH-100 plus

E-Gas HKH-160 plus

E-Gas HKH-250 plus

Flow rate (ml/min)

100

160

250

Weight (kg)

17

17

17

Cascading

None

Purity

99.9996%

Display

Parameters, Status, Alarms

LED Indicators

On / off, Ready, Error

Membrane

Polymer Electrolyte Membrane(PEM)

Dryer

Exclusive static system dryer

Max Outlet Pressure

adjustable up to 7 bar (102 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<10uS)

Connections

1/8 swage lock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

230W x 430H x 353L

Certifications

CE, CSA, FCC

Options

RS232C or RS485, Aurore ll, External contracts, PC-control

Flow rate: 100 to 250 ml/min, Purity 99.9996%
e-Gas NM Plus (EL70082)
The EZZILAB Hydrogen Generators offer a safe, economical and convenient alternative gas cylinders. The e-GAS NM Plus Series provides superior performance with proprietary electrolytic cell technology combined with high quality components and a unique hydrogen drying solution. Ideal for use with gas chromatography detectors such as FID , NPD, and FPD.

e-GAS NM PLUS SERIES FEATURES:
• Flow rate from 100 to 1000 ml/min
• Purity 99.99999%
• Pressure up to 11 bar (160 psig)
• Minimal maintenance
• Unique drying membrane - no desiccant cartridges required
• Unique 100% titanium electrolytic cell
• 2 year standard warranty

BENEFITS
CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

IMPROVED SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solution are Used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.

SPECIFICATIONS

Models

e-Gas NM 100 plus

e-Gas NM 160 plus

e-Gas NM 250 plus

e-Gas NM 300 plus

e-Gas NM 500 plus

e-Gas NM 600 plus

e-Gas NM 1000 plus

Flow rate (ml/min)

100

160

250

300

500

600

1000

Weight (kg)

17

17

17

17

18

18

20

Cascading

Yes (up to 32 units)

Purity

99.99999%

Display

Operating parameters, system status, alarms and touch screen

LED Indicators

Power on/off, system ready, errors

Membrane

Polymer Electrolyte Membrane(PEM)

Dryer

Exclusive cold dual dynamic regeneration system

Max Outlet Pressure

11 bar (160 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<10uS)

Cascading

The exclusive cascading option allows up to 32 units to be connected in series, producing _ow-rates of up to 32 litres also via Intranet

Connections

1/8 swage lock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

230W x 450H x 370D

Certifications

CE, CSA, FCC

Options

RS232/RS485 and USB, autore_ll, external contacts, PC control, Intranet


Flow rate: 100 to 1000 ml/min, Purity 99.99999%
e-Gas PG Plus (EL70081)
The EZZILAB Hydrogen Generators offer a safe, economical and convenient alternative gas cylinders. The e-GAS PG Plus Series provides superior performance with proprietary electrolytic cell technology combined with high quality components and a unique hydrogen drying solution. Ideal for use with gas chromatography detectors such as FID , NPD, and FPD.

e-GAS PG PLUS SERIES FEATURES:
• Flow rate from 100 to 600 ml/min
• Purity 99.9999%
• Pressure up to 11 bar (160 psig)
• Minimal maintenance
• Unique drying membrane - no desiccant cartridges required
• Unique 100% titanium electrolytic cell
• 2 year standard warranty

BENEFITS
CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

IMPROVED SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solution are Used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.

SPECIFICATIONS

Models

e-Gas PG-100 plus

e-Gas PG-160 plus

e-Gas PG-250 plus

e-Gas PG-300 plus

e-Gas PG-500 plus

e-Gas PG-600 plus

Flow rate (ml/min)

100

160

250

300

500

600

Weight (kg)

17

17

17

17

18

18

Purity

99.9999%

Display

Operating parameters, system status, alarms and touch screen

LED Indicators

Power on/off, system ready, errors

Membrane

Polymer Electrolyte Membrane(PEM)

Dryer

Exclusive cold dual dynamic regeneration system

Max Outlet Pressure

11 bar (160 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<10uS)

Cascading

The exclusive cascading option allows up to 32 units to be connected in series, producing _ow-rates of up to 20 litres also via Intranet

Connections

1/8 swagelock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

230W x 450H x 370D

Certi_cations

CE, CSA, FCC

Options

RS232/RS485 and USB, autore_ll, external contacts, PC control, Intranet


Flow rate: 100 to 600 ml/min, Purity 99.9999%
Per Page      1 - 9 of 9